Physical

Property Value Typical ASTM Test
Chemical Designation (PA-6) Cast Polyamide
Trade Names (®, ™) Sustamid GHS, MC 901, Tecast, ZL 1100 Blue, Nycast XHA Blue
Color Blue
Density (g/cm^3) 1.16 D 792

Mechanical

Property Value Typical ASTM Test
Modulus of Elasticity (Tensile Test) (psi) 500000 D 638
Tensile Strength at Yield (psi) 11750 D 638
Elongation at Break (%) 25 D 638
Flexural Strength (psi) 16250 D 790
Modulus of Elasticity (Flexural Test) (psi) 460000 D 790
Compression Strength: 10% Strain (psi) 14750 D 695
Compression Modulus (psi) 362500 D 695
Impact Strength (Izod) (ft-lbs/in) 1.75 D 256
Hardness (R) 115 D 785
Hardness (D) 82 D 785
Coefficient of Friction (Kinetic, 40 psi, 50 fpm) 0.26 D 3702

Thermal

Property Value Typical ASTM Test
Melting Point (°F) 430 D 3418
Deflection Temperature (°F) (66 psi) 375 D 648
Deflection Temperature (°F) (264 psi) 300 D 648
Service Temperature Continuous (°F) 250
Service Temperature Intermittent (°F) 350
Thermal Expansion (CLTE) (in/in/°F) 5.00E-5 D 696

Electrical

Property Value Typical ASTM Test
Dielectric Strength (V/mil) 550 D 149
Dielectric Constant (1MHz) 3.7 D 150

Other

Property Value Typical ASTM Test
Moisture Absorption (%) (24 Hours) 0.55 D 570
Moisture Absorption (%) (Saturated) 5 D 570
Flammability HB
The data stated are typical values intended for reference and comparison purposes only. The data should not be used as a basis for design specifications or quality control. The information is provided as a guide to the best of our knowledge and given without obligation or liability. Testing under individual application circumstances is recommended.