What is the Material: Cast Nylon Oil FG is a semi-crystalline material filled with oil lubricant, which is Food Safe.

Key Material Features: This material is beneficial in applications requiring high load capabilities, reduced friction, and where external lubrication is to be avoided, while maintaining the properties of other nylon materials including mechanical properties, wear resistance, abrasion resistance, and dimensional stability.

Other Considerations: Cast nylons are often used as wear parts. The properties of the materials often make them beneficial alternatives to steel and bronze parts. Note: There is a green oil filled Cast Nylon that is not Food Grade, but there is natural colored food grade oil filled cast nylon available.

Physical

Property Value Typical ASTM Test
Chemical Designation (PA-6) Cast Polyamide
Trade Names (®, ™) Nycast Nyloil
Filler Oil
Color Natural
Density (g/cm^3) 1.15 D 792

Mechanical

Property Value Typical ASTM Test
Modulus of Elasticity (Tensile Test) (psi) 425000 D 638
Tensile Strength at Yield (psi) 10250 D 638
Elongation at Break (%) 45 D 638
Flexural Strength (psi) 15000 D 790
Modulus of Elasticity (Flexural Test) (psi) 425000 D 790
Compression Strength: 10% Strain (psi) 14250 D 695
Compression Modulus (psi) 350000 D 695
Impact Strength (Izod) (ft-lbs/in) 1.6 D 256
Hardness (R) 113 D 785
Hardness (D) 77 D 785
Coefficient of Friction (Kinetic, 40 psi, 50 fpm) 0.12 D 3702

Thermal

Property Value Typical ASTM Test
Melting Point (°F) 430 D 3418
Deflection Temperature (°F) (66 psi) 350 D 648
Deflection Temperature (°F) (264 psi) 250 D 648
Service Temperature Continuous (°F) 230
Service Temperature Intermittent (°F) 330
Thermal Expansion (CLTE) (in/in/°F) 5.00E-5 D 696

Electrical

Property Value Typical ASTM Test
Dielectric Strength (V/mil) 550 D 149
Dielectric Constant (1MHz) 3.7 D 150

Other

Property Value Typical ASTM Test
Moisture Absorption (%) (24 Hours) 0.5 D 570
Moisture Absorption (%) (Saturated) 4.5 D 570
The data stated are typical values intended for reference and comparison purposes only. The data should not be used as a basis for design specifications or quality control. The information is provided as a guide to the best of our knowledge and given without obligation or liability. Testing under individual application circumstances is recommended.